Oxygen Bomb Calorimeter

Heat of combustion of materials is important characterize parameters to calculated building materials release heat and fire basic data. The bomb calorimeter is designed according to ISO 1716-2002.
Availability:
Quantity:
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
  • GD-ISO1716; GDY-1A; GDY-1A+

  • GOLD

  • 9031809090

Oxygen Bomb Calorimeter

(GD-ISO1716, GDY-1A)

Oxygen Bomb Calorimeter


   Introduction:   

GD-ISO1716 Oxygen Bomb Calorimeter:

Heat of combustion of materials is important characterize parameters to calculated building materials release heat and fire basic data.The GD-ISO 1716 Oxygen bomb calorimeter is designed according to ISO 1716.


GDY-1A Oxygen Bomb Calorimeter:

1.GDY-1A Oxygen Bomb Calorimeter is designed and made as per the National Standard of People’s Republic of China GB/T213 “Test Methods for Calorific Value of coal”, GB/T384 “Test Methods for Calorific Value of Petroleum Products” and Calibration Regulation of People’s Republic of China JJG672 “Oxygen Bomb Calorimeter”, as well as Company Standard of Shanghai Q/YXYY 10 “XRY-1 Series Oxygen Bomb Calorimeter”.

2.The heat capacity of the instrument is 14400~14500 J/K, and it is suitable for the determination of water-free oil products (gasoline, jet fuel, diesel oil and fuel oil, etc.) and combustible material such as coal, coke, paraffin wax content determination of calorific value.



   Standard:   

  • ISO 1716 

  • GB/T 14402

  • GB/T8624 



   Feature:   

GD-ISO1716 Oxygen Bomb Calorimeter:

1.  GD-ISO 1716 Oxygen Bomb Calorimeter including: calorimeter apparatus, high-pressure oxygen bomb, cold water installations, computer and control system (which can record and display the curve), LCD screen and software.

2.  Crucible made of stainless steel.

3.  Box paint treatment; all internal parts are made of stainless steel, corrosion-resistant, easy to clean.

4.  Ignition wire break is detection, and automatic ignition.

5.  The test procedure automatically turn off.

6.  Test abnormalities has sound alarm.

7.  Computer control system: Control box with USB / RS232 serial port with an external brand desktop or laptop operating control; High degree of automation, test procedure safe and reliable, easy to operate.


GDY-1A Oxygen Bomb Calorimeter:

1) GDY-1A Oxygen Bomb Calorimeter uses a self sealed oxygen bomb, all the structure of the use of stainless steel, the strength is sufficient to withstand the maximum pressure generated by solid combustion (70 ~ 60 ATM), and can withstand the pressure of liquid fuel generated by the greater pressure.
2) The inner tube of the instrument is made by stainless steel sheet, section of pears, put the barrel of water was 3000 grams, water cylinder with electric blender, to ensure that the inner tube water bath temperature uniformity.
3) GDy-1A Oxygen Bomb Calorimeter of the external water jacket is a double container and experiment when filled with water, through the water jacket mixer to cylinder in uniform temperature, formed to meet the test requirements of the constant temperature environment.



   Specification:   

GD-ISO1716 Oxygen Bomb Calorimeter
Bomb capacity
(300 ± 50) mL.
Oxygen bomb pressure range
0.5 ~ 3.5MPa, no leakage. The bomb pressure 21Mpa.
Timer
accuracy of 0.5s;
Maximum power
0.5KW;
Ambient temperature
(10 ~ 35) ℃, humidity ≤80%;
Heat capacity of the instrument
about 10000J / K;
Heat repeatability error
≤0.2%;
Temperature range
(4.5-50) ℃;
Temperature detection
0.0001 ℃ resolution, using the PT100 sensor;
Inner cylinder volume
2000ml; Oxygen bomb Sealing
Motor power 3W; stirring speed
Power supply voltage
AC220V ± 10% 50Hz

 

GDY-1A Oxygen Bomb Calorimeter
Heat capacity (14000 ~ 15000)J/K
Temperature resolution 0.001 K
Thermal error ≤60J/g
Temperature measurement range 10 ℃~35 ℃
Repeatability error ≤0.2% (Grade C)
Pressure endured by Oxygen bomb 20 MPa
Ambient temperature 15 ℃~28 ℃ (room temperature), 
The temperature fluctuation during each test should be not more than 1 ℃
Storage Temperature data 31
Ambient humidity less than 85%
Power supply AC(220±5%)V,50Hz
Total power consumption less than 150W
Dimensions 600 mm × 460 mm × 430 mm (length × width × height, PC is not included)
Note: If the test sample is pulverized coal samples, in order to obtain better test results, 
we recommend separately of the company's private press cake machine.



   Product Show:   

bomb calorimeter (3)

GDY-1A

GDY-1A+ Oxygen Bomb Calorimeter

Bomb Calorimeter (6)


   Welcome to contact us:  

Contact Person: Kiana Feng

Whatsapp/Wechat: +86 15922982738

Mobile: +86 15922982738

Fax: +86-23-62940030

Email: gold20@hy-industry.com


Previous: 
Next: 
Send Us A Message

  Site Map

Contact Us

  25F, China Resources Building, Xiejiawan, Jiulongpo DistrictChongqing,China
  +86-23-62984892
  +86-15922982738
   
gold20@hy-industry.com
  +86-23-62940030

Quick Links

Send Us A Message

​Copyright © 2018  Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd. All Rights Reserved.