Views: 12 Author: Site Editor Publish Time: 2021-10-14 Origin: Site
Fire Test Standards for Building Materials in Various Countries
European standard:
EN 13501-1:2007:Fire classification of construction products and building elements-Part1: Classification using data from reaction to fire tests
Non-floor materials A1, A2, B, C, D, E, F | Class A1: EN ISO 1182 non-combustibility and EN ISO 1716 calorific value of combustion Class A2: EN 13823 single combustion and ISO 1182 or ISO 1716 combustion heat value Class B, C, D: EN ISO 11925-2 flammability test and EN 13823 single combustion Class E: EN ISO 11925-2 flammability test Level F: Fails to meet the requirements of Level E. |
Floor covering materials A1fl ,A2fl ,Bfl,Cfl, Dfl, Efl, Ffl | A1fl: EN ISO 1182 non-combustibility test and EN ISO 1716 heat of combustion Class A2fl: ISO 9239-1 and ISO 1182 non-combustibility or ISO 1176 combustion heat value Bfl, Cfl, Dfl level: EN ISO 11925-2 flammability test and ISO 9239-1 radiant heat source test Efl level: EN ISO 11925-2 flammability test Ffl level: fail to meet Efl level requirements |
Linear fittings A1L, A2L, BL,CL,DL,EL,FL | Class A1L: EN ISO 1182 non-combustibility test and EN ISO 1716 combustion heat value A2L level: EN 13823 single combustion and ISO1182 non-combustibility or ISO 1716 combustion heat value BL, CL, DL level: EN ISO 11925-2 flammability test and EN 13823 single combustion) EL level: EN ISO 11925-2 flammability test FL level: Fails to meet the Class E requirements. |
EN13823 Reaction to fire tests for building products ― Building products excluding floorings exposed to the thermal attack by a single burning item
ENV 1187 Fire tests on building materials and structures — Test methods for external fire exposure to roofs
British Standard:
BS 476-3 Fire tests on building materials and structures — Part 3: Classification and method of test for external fire exposure to roofs
BS 476-4 Fire tests on building materials and structures- Part 4: Non-combustibility test for materials
BS476-5 Fire tests in building materials and structures Part 5: method of test for ignitability
BS 476-6 Fire Tests on Building materials and structures – Method of test for fire propagation for products
BS 476-7 Fire Tests on Building materials and structures – Method of test to determine the classification of the surface spread of flame of products
BS 476-11 Fire tests on building materials and structures — Part 11: Method for assessing the heat emission from building materials
BS 476-12 Fire tests on building materials and structures-Part 12: Method of test for ignitability of products by direct flame impingement.
BS 476-15 Fire Tests on Building Materials and Structures Part 15: Method of Measuring the Rate of Heat Release of Products
BS 7955 Containment nets and sheets on construction works – Specification for performance and test methods
BS 5839-1:Fire detection and fire alarm systems for buildings — Part 1: Code of practice for system design, installation, commissioning and maintenance
BS 5803-3:Thermal insulation for use in pitched roof spaces in dwellings. Specification for cellulose fibre thermal insulation for application by blowing.
BS 5803-2:Thermal insulation for use in pitched roof spaces in dwellings- Part 2: Specification for man-made mineral fibre thermal insulation in pelleted or granular form for application by blowing.
Australian Standard:
AS/NZS 1530.1:Methods for fire tests on building materials,components and structures – Combustibility test for materials
AS/NZS 1530.2:Methods for fire tests on building materials,Components and structures – Test for flammability of materials
AS/NZS 1530.3:Methods for fire tests on Building Materials,Components and Structures – Part 3: Simultaneous Determination of Ignitability,Flame Propagation. Heat Release and Smoke Release
AS/NZS 3837:Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter
American standard:
ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM E136 Non-combustibility test
ASTM E 162: Standard test method for surface flammability of materials using a radiant heat energy source.
ASTM E648:Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat
ASTM E1354 Method of test for heat and smoke release rates for materials and products using an Oxygen Consumption Calorimeter
ASTM D3675: Standard test method for surface flammability of flexible cellular materials using radiant heat energy source.
ASTM D2843 Standard Test Method for Density of Smoke from the Burning or Decomposition of plastics
ASTM E 970:Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
UL 723 Standard Test Method for Surface Burning Characteristics of Building Materials
German standard:
DIN 4102-1 Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing
French standard:
NF P92-507: Building- Construction and furnishing materials- Classification according to reaction to fire
NF P92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigid material or flexible materials thicker than 5mm
NF P92-503: Safety against fire: Building materials – Reaction to fire tests. Electrical burner test used for flexible materials
NF P 92-504: speed of spread of flame test used for the materials which are not intended to be glued on a rigid substrate.
NF P 92-505: Dripping test with electrical radiator, used for melting materials
International standards:
ISO 1716 Reaction to fire tests for building Products- Determination of the heat of combustion
ISO 1182 Reaction to fire tests for products — Non-combustibility test
ISO5658-2 Reaction to fire tests-spread of flame-Part 2: Lateral spread on building products in vertical configuration
ISO5660-1 Reaction to fire tests-Heat release, smoke production and mass loss rate-Part 1: Heat release rate (cone calorimeter method)
ISO 5660-2: Reaction to fire tests — Heat release, smoke production and mass loss rate — Part 2: Smoke production rate (dynamic measurement)
ISO 5659-2: Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test
ISO11925-2:Reaction to fire tests-Ignitability of building products subjected to direct impingement of flame-Single-flame source
Canadian Standard:
CAN/ULC-S102-10:Standard method of test for surface building characteristics of building material and assemblies
CAN/ULC-S102-3:Standard method of fire test of light diffusers and lenses.
CAN-ULC-S102-2:Standard method of test for surface building characteristics of flooring, floor coverings, and miscellaneous materials and assemblies.
CAN/ULC-S135:standard test method for the determination of combustibility parametres of building materials using an oxygen consumption calorimeter.
CAN/ULC-S127:standard corner wall method of test for flammability characteristics of Non-melting foam plastic building materials.
CAN/ULC-S114-05:Standard method of test for determination of Non-combustibility in building materials
CAN/ULC-S129:standard method of test for smoulder resistance of insulation(basket method)
Site Map
Copyright © 2018 Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd. All Rights Reserved.