Availability: | |
---|---|
Quantity: | |
GD-AIT-25
GOLD
Gas Autoignition Point Temperature Tester
Model: GD-AIT-25
Standard: ISO817 etc.
Test object: flammable gas
Test index: Autoignition point temperature
Mian Feature:
● Integrated design, using floor-standing movable cabinets for complete installation.
● High-precision gas distribution device can accurately complete gas proportioning.
● Superior gas mixing and stirring system, fully stir the mixed gas evenly.
● Electric spark ignition method, other methods can also be selected for explosion triggering.
● Computer automated control method, the entire test process is controlled by test software.
Reaction vessel | standard quartz Erlenmeyer flask |
Injection mode | Automatic injection mode |
Injection range | accuracy 0.05% |
Detection method | Photoelectric detection, automatic detection of spontaneous ignition point |
Gas distribution method | Partial pressure method gas distribution method |
Mixer | 20-800r/min |
Temperature control range | room temperature ~ 800℃ |
Temperature control | accuracy ±0.1℃ |
Temperature measurement parts | top, center and bottom of test flask |
Heating method | Electric heating method, using PID temperature control |
Power requirements | 220V, 50HZ, 200W |
Gas requirements | Air compressor gas (no oil and no water) |
Gas Autoignition Point Temperature Tester
Model: GD-AIT-25
Standard: ISO817 etc.
Test object: flammable gas
Test index: Autoignition point temperature
Mian Feature:
● Integrated design, using floor-standing movable cabinets for complete installation.
● High-precision gas distribution device can accurately complete gas proportioning.
● Superior gas mixing and stirring system, fully stir the mixed gas evenly.
● Electric spark ignition method, other methods can also be selected for explosion triggering.
● Computer automated control method, the entire test process is controlled by test software.
Reaction vessel | standard quartz Erlenmeyer flask |
Injection mode | Automatic injection mode |
Injection range | accuracy 0.05% |
Detection method | Photoelectric detection, automatic detection of spontaneous ignition point |
Gas distribution method | Partial pressure method gas distribution method |
Mixer | 20-800r/min |
Temperature control range | room temperature ~ 800℃ |
Temperature control | accuracy ±0.1℃ |
Temperature measurement parts | top, center and bottom of test flask |
Heating method | Electric heating method, using PID temperature control |
Power requirements | 220V, 50HZ, 200W |
Gas requirements | Air compressor gas (no oil and no water) |
Site Map
Copyright © 2018 Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd. All Rights Reserved.